Wednesday, December 2, 2009 XStep Café – Session 16 (No Audio)
VN:F [1.9.22_1171]
Rating: 5.0/5 (1 vote cast)

Session Recording

MDA: Creating notifications / Rework scenario

Unfortunately the audio signal of the this session was not recorded due to a technical issue. I know now how to avoid this in the future but still the audio for the last session is gone. So at least I tried to capture what I have explained in some session notes and I hope that you can at least find some value in it. Maybe we can also repeat some of this in one of the next sessions.

Link to original flash recording

Session Timeline
Time Details
00:00:48 1) Ragu’s issue with non-tabular parameters assignment to proc. mess. in table
00:01:16 Tabular and non-tabular parameters defined
00:01:45 Value help for ‘Process order’ does not allow to select X_ORDER (because it is not a tabular parameter)
00:02:00 You need to enter the parameter X_ORDER manually
00:02:15 A tabular parameter can be selected without problems
00:03:01 2) MDA: Creating notifications based on conditions
00:04:05 How to run the SAP ODA connector in foreground to see what’s happening on the client.
00:04:50 OPC setup of the Matrikon Simulation Server as an A&E data source
00:06:00 – Make sure that the severity filter is set at least for a very large interval to capture all events
00:06:15 Create a test subscription (see also the black ODA window)
00:07:00 Example how to use the A&E subscription in XSteps
00:07:24 The buton ‘Test’ is an MDA element which is triggered also on the event shown before. It also reads additional event data
00:08:20 Check the process message created on that event
00:10:00 If no PI Sheet with event subscriptions is active, no events are sent to ERP
00:11:00 Usage of CO69 to capture events in background (no order relation though)
00:12:30 How the example is set up with XSteps
00:16:00 – MDA element
00:17:10 – Writing of the non-tabular data of the MDA element to tabular parameters (to fill the process message)
00:17:30 – Set a status parameter for the automatic completion of the table line
00:19:04 3) Rework
00:20:30 Example order. Operation 0030 is used. 2 materials are assigned to that operation.
00:21:50 Amongst normal SXS for confirmation and goods issue a special SXS is attached to operation 0030 to enable additional rework XSteps
00:22:00 PI Sheet: regular instructions executed
00:23:00 Rework is triggered
00:24:40 Execute the new PI Sheet with rework instructions
00:25:30 Enable unplanned goods movements
00:27:00 Check order for confirmation data and documented goods movements
00:29:30 Show some details of the function module used to create the new control recipe (no coding provided)
00:32:03 4) Peter’s problem mixing automatic characteristics and symbol valuation
00:34:30 How to include a parameter (e.g. ‘PAR1’) into a long text using ‘&’
00:36:00 – use &PAR1& and NOT &PPPI_MATERIAL& (which worked with the old process instructions)
00:38:31 5) Flag in O10C (external system)
00:39:00 Flag ‘Creation with XSteps’ in TA O10C (Control recipe destinations)
00:39:30 1st alternative to use XSteps for external systems: Do NOT use the flag ‘Creation with XSteps’
– Create manual process instructions and use parameter valuation (e.g. &A_ORD&)
– Provide process instruction type manually (e.g. ‘3 process message subscription’)
– Provide the category of the process instruction manually (e.g. A_CONS_1)
00:41:00 2nd alternative: Use the flag ‘Creation with XSteps’
– NO manual created process instruction
– All parameters get transfered into the control recipe including values
00:42:30 Example of an XML structure of an external control recipe:
– There are NO process instruction categories (only a dummy placeholder)
– Also structural XStep information is included (blocks, parameter names,…)